Sabiana IRC board-remote c Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Controlos remotos Sabiana IRC board-remote c. Cassette fan coil Climmy TopLine Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Climmy TopLine

Cassette fan coilClimmy TopLineTechnicalCatalogue

Página 2 - Introduction

Packed unitDimensions1050 400 1000 200ABCDmm47 3910 6kg kgWeightspacked unitWeightsunpacked unit44 36UNIT DIFFUSERkg kgModelWeightspacked unitWeightsu

Página 3

Model1231231231231231233,32,22,53,92,62,94,22,83,13,32,22,54,22,83,14,83,23,63,92,62,94,53,03,45,23,43,93,52,22,74,12,63,24,83,03,83,82,43,04,62,83,65

Página 4 - EUROVENT Certification

Spigotfor air distributionMAIN AIR INLETAIR INTAKETwo air outlets are providedon the side of the unit for connectionto separate supply air outlets.The

Página 5 - Emission

- Manual speed switch.- Manual Summer/Winter switch.- Electronic thermostat for fan control(ON-OFF).- Electronic thermostat for valve(s) control(O

Página 6 - Emission of 4 pipe units

Same characteristics as TMO-T, adding:- Manual or automatic speed switch.- Electronic thermostat for fan control (ON-OFF).- Electronic thermostat f

Página 7

LEGENDSEC 1 = TopLine electrical boardMC = Control electrical boardM = FanE = Water valveE1 = Warm water valveE2 = Chilled water valveTMO 503 -

Página 8

AL = Safety relay - high condensate levelLEGENDSEC 1 = TopLine electrical boardMC = Control electrical boardM = FanE = Water valveE1 = Warm

Página 9

TMO-DI connectionwith 2 valvesTMO-DI connectionwith 1 valveTo be installed on the wallor in the electric switch box.- Manual or automatic speed switc

Página 10 - Dimensions and weights

SEC1 = TopLine electrical boardTME = L.T.C.O. sensorE = Valve set (2 pipe installation)E1 = Hot water valve set (4 pipe installation)E2 = Ch

Página 11 - Air throw

AccessoriesTME low temperature cut-out thermostatSuitable for wall controls only (not infra-red remote control). To be fitted between the coil fins;wh

Página 12

Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: thenew TopLine chilled water casse

Página 13 - Electronic controls

AccessoriesON-OFF valves with thermoelectric actuatorValve set, 2 or 3 ways, ON-OFF, with thermoelectric actuator.The set includes connection pipes an

Página 14 - Identification Code

The TopLine 2 pipe models are available with electric resistance that is controlled in place of the heating battery valve.The elect

Página 15 - TMO 503 - SV2

IntroductionTopLine ECM = TL = TL-ECMThe TopLine ECM series uses an innovative brushless synchronous permanent magnet electricmotor contr

Página 16

INTAKE GRID AND DISTRIBUTION OF THE AIRIntake grids, frame and adjustable air distribution louvers on each side, made from ABS.RSNA version : white A

Página 17 - TMO-DI connection

3,0 4,01,4 2,1 2,1820 x 820 x 303575 x 575 x 2757105,293,695,899099,47,234251011307,725,538,83132818,514,9473832177010,757,9412,73184833,628,857481086

Página 18 - Repeater for TMO-DI

7/12 °C10/15 °C14/18 °CKKK0,90,720,50,940,780,581,060,90,727/12 °C10/15 °C14/18 °CKKK0,820,560,350,890,630,411,110,820,52Water (°C) Air (°C) 25-1826-1

Página 19 - CH 15-25

7/12 °C10/15 °C14/18 °CKKK0,90,720,50,940,780,581,060,90,727/12 °C10/15 °C14/18 °CKKK0,820,560,350,890,630,411,110,820,52Water (°C) Air (°C) 25-1826-1

Página 20 - Valves pressure drop

Working conditionsPressure dropfor cooling batteryPressure dropfor heating battery2 pipe installation4 pipe installationTopLine ECMWater side pressure

Página 21 - TL 1.2T-E/2.2T-E/3.2T-E

790 350 750 150ABCDmm30 2463kg kgWeightspacked unitWeightsunpacked unit28 22UNIT DIFFUSERkg kgECM ModelWeightspacked unitWeightsunpacked unitPacked un

Página 22 - autonomously

UNIT DIFFUSER1050 400 1000 20010 6Packed unitDimensionsABCDmm47 39kg kgWeightspacked unitWeightsunpacked unit44 36UNIT DIFFUSERkg kgECM ModelWeightspa

Página 23 - Main components

INTAKE GRID AND DISTRIBUTION OF THE AIRIntake grids, frame and adjustable air distribution louvers on each side, made from ABS.RSNA version : white

Página 24

1233,32,22,53,92,62,94,22,83,11233,32,22,54,22,83,14,83,23,61233,92,62,94,53,03,45,23,43,91233,52,22,74,12,63,24,83,03,81233,82,43,04,62,83,65,43,44,2

Página 25

LEGENDSEP = Pump control boardBLAC = Inverter boardM = Electronic motorCONTROLLER = ControllerFor this cassette configuration, the 1-10

Página 26

TopLine ECMFresh air kitThis is used to introduce primary air into the environment directly through the diffuser. The kitincludes a f

Página 27 - Water side pressure drop

Valve set, 2 or 3 ways, ON-OFF, with thermoelectric actuator.The set includes connection pipes and holders.Note: The main battery valve connectionNot

Página 28

All the Climmy TopLine /TopLine ECM units can be supplied in MB version. This version includesa wide range of controls, including the infra-red remot

Página 29

The MB power electronic board,mounted as per standard on the TLand TLdifferent functions and adjustment modes,in order to meet the installation requir

Página 30

Wall mounted control with displaythat allows controlling one or more unitsin Master/Slave mode. The control is equippedwith internal sensor to detect

Página 31 - • Maximum speed 10Vdc;

The infra-red remote control allows setting by a remote position the fan coil operation parameters.RCS-RT03RCSRSRT039079117907911690663383021203RT03 i

Página 32 - DENTIFICATION

The T2 sensor can be combined with MB boards to be placed on the water supply pipe upstream 3 way valves(not to be used with 2 way

Página 33 - 2 way valves 3 way valves

Another option available for the serial communication betweenthe units is the possibility to connect up to 60 Cassette units inseries and

Página 34 - -MB versions

3101,841,352,223164,94,13324250,114202,341,752,904027,66,34031320,155202,682,043,354619,78,24536440,203202,251,572,563874,63,53324250,115003,342,393,9

Página 35 - MB power electronic board

IntroductionThe MCT version has been designed for all environments where false ceilings are not featuredor cannot be constructed.The co

Página 36 - T-MB wall mounted control

Dimensions and WeightsTL 0.2T-MCT / TL 1.2T-MCT / TL 2.2T-MCT / TL 3.2T-MCTCasing code: 9079240Casing weight: 5 kg (7,5 kg with the packaging)TL 4.2

Página 37 - TopLine /TopLine ECM

Assembly diagramTopLine MCT42

Página 38 - MB wall mounted control

maintaining the essential characteristics of the types described and illustrated, to make, at any time, without therequirement to pr

Página 39 - PSM-DI multifunction control

386310237482417356787593412903702520111886573416831146876201514718762,241,801,382,802,422,074,573,452,395,254,083,026,505,034,279,786,675,0911,728,555

Página 40 - TopLine MCT

Model SpeedAirflowEWT 45 - LWT 40°C EWT 50 - LWT 40°C EWT 60 - LWT 50°C EWT 70 - LWT 60°C EWT 80 - LWT 70°Cl/hm3/h kW l/h kW l/h kW l/h kW l/h kWWater

Página 41 - Dimensions and Weights

7105003208806104301500970710182012807102792261653152552057205414418246514411,621,320,961,831,481,194,183,142,564,793,792,56139113831561271034933652915

Página 42 - Assembly diagram

°CK200,94300,90400,86500,82600,78700,74800,70°CK401,14501,08601,02700,96800,90°CK200,94300,90400,86500,82600,78700,74800,70Water flowAir flowSupplyMAX

Página 43

790 350 750 150ABCDmm30 2463kg kgWeightspacked unitWeightsunpacked unit28 22UNIT DIFFUSERkg kgModelWeightspacked unitWeightsunpacked unitPacked unitDi

Comentários a estes Manuais